Heater
power connector- High temperature power adaptor, DIN 49490 connnector, European
Plug, Flange Inlet, Fiberglass cloth tape, Flexible mica, Rigid mica sheet, Mica
washer, High temperature insulations, Ceramic fiber paper, Ceramic heater insulations
Din
49490 2 or 3 wire grounding connectors- 16 amps 250Vac, 10 Amps 250Vdc, 200°C
Din
49458 A/B, CEE connectors 2 poles 3 wires grounding 16 Amps 250VAC, 200°C
High
temperature inlet 16 Amps 250VAC/ 10 AMPS 250Vdc 2 poles
Din
49458 (VDE 035) connectors 10 Amps 250Volts 155°C
Plugs
and connectors, 75C -Locking and straight blade 15 Amps 250V 2 poles 3 Wires grounding
Heater
high temperature inlet for DIN 49490 connectors
High
temperature IEC inlet connectors
Please
note: We ship to Paypal confirmed address only when payment is charge through
Paypal!!
Band
heater plugs DIN connectors (straight) (porcelain/aluminum shell) rated at 25A,
380VAC Part No. EP90
Canadian
Customers*
$15.00
Band
heater plugs (90 degrees bend) porcelain/aluminum shell rated at 25A, 380VA, c/w
strain relief spring. P/N EP90S
US
Customers
Canadian Customers
$15.00
Heater
plug DIN connectors rated at 25A 380VAC P/N EP180
US Customers
$15.00
Heater
plug DIN connectors rated at 25A 380VAC, c/w strain relief spring.
P/N EP180S
Canadian
Customers
US Customers
$15.00
Plug
inlet, 16A high temperature inlet for DIN 49490 Connector
P/N IEP-2C
Canadian Customers
US customers
$5.00
Please
note: We ship to Paypal confirmed address only when payment is charge through
Paypal!!
Inlet
power jack box. Available in stainless steel, steel, aluminum and painted steel.
One side removable panel with screws and knockout. Many sizes available.
IEPBOX-3SS
$99.00 Stainless steel 304 & 3 European plug Inlets
Specify
your sizes
Band heater connector c/w 6 feet of 12 AWG cable, 3 cables(fiberglass over silicone
insulations). Cable rated at 150°C 300VAC Part
No. EP1806FT12GA $30.00CAD
Canadian
Customers
US Customers
$30.00
European
plug band heater connector c/w 6 feet of 12 AWG cable, 3 cables (fiberglass over
silicone insulations). Cable rated at 150°C 300VAC Part
No. EP906FT12GA $30.00CAD
Canadian
Customers
US Customers
$30.00
European
plug heater connector c/w 6 feet of 12 AWG cable, 3 cables ( Fiberglass over silicone
insulations & SS304 braid over wires). Cable rated at 150°C 300VAC Part
No. EP906FT12GASSB $37.00CAD
Canadian
Customers
US Customers
$37.00
Din
connectors c/w 6 feet of 12 AWG cable, 3 cables ( fiberglass over silicone insulations
& SS304 braid over wires). Cable rated at 150°C 300VAC Nickle plated copper
Part No. EP1806FT12GASSB $38.00CAD
Canadian
Customers
US Customers
$37.00
Din connectors c/w 6 feet of 18 AWG cable, 3 cables ( fiberglass over mica insulations
and PVC fiberglass sleeve). MGT cable rated at 450°C 600VAC Part
No. EP906FT18GAMGTPVC $38.00CAD
Canadian
Customers
US Customers
$38.00
European
plug - Din connectors c/w 6 feet of 18 AWG cable, 3 cables ( fiberglass over mica
insulations and PVC fiberglass sleeve). Cable rated at 450°C 600VAC nickle
plated copper MGT Part No. EP1806FT18GAMGTPVC
$39.00CAD
Canadian Customers
US Customers
$38.00
Please
note: We ship to Paypal confirmed address only when payment is charge through
Paypal!!
High
temperature ceramic terminal block (porcelain), 15A/240V, 445°F (230°C)
Wire Dia. 3/16", 2 legs, plated brass connectors part#
CTBS2 $3.50CAD
Mica has a high dielectric strength and excellent chemical stability, making
it a favoured material for manufacturing capacitors for radio frequency applications.
It has also been used as an insulator in high voltage electrical equipment, and
between the bars of commutators in Direct Current motors and generators. Mica
is used because it can be split into very thin slices, and this keeps its thermal
resistance low while retaining sufficient dielectric strength to prevent current
from flowing across it at moderate voltages. The insulation is usually necessary
when the heat sink is earthed (grounded) while the electronic component's metal
surfaces will be connected to a power supply or signal line. If they were in direct
contact this could form a short circuit. Heat sink insulation can also be necessary
to prevent the heat sink from acting like an antenna if the component is connected
to a rapidly varying signal.